MAYEN / DE

Reversepowerplant meets agriculture

In Mayen, Ralph Grauel implements a sophisticated energy solution on the site of his father's abandoned farm. With his experience in the field of energy technology, Ralph Grauel has the necessary expertise for the use of SYNCRAFT technology. The biomass is purchased and dried directly on site before being converted into renewable energy and green carbon in the SYNCRAFT CW 1800-500 Reversepowerplant in a way that conserves resources. The plant, which has been in operation since 2024, generates 500 kW of electrical power and 740 kW of thermal power with a fuel requirement of 362 kg/h on an area of 215 m². The products and their application: Ralph Grauel currently uses the heat generated to heat his parents' home and his own house. He would like to use the remaining heat to dry woodchippings. This climate-positive technology CO₂ avoided 3,500 tons of CO₂ avoided per year and actively removes an additional 1,500 tons of CO₂ from the atmosphere. A special feature of this plant is its customized design: As a "slimmed-down" version of our standard backwards power plant, the customer purchased a great many components themselves - including drying, moving floor, biomass feed screws, cooler and room ventilation. This smart solution shows how technical expertise and SYNCRAFT technology can be optimally combined to create cost-efficient energy solutions.

“I have more than 20 years of experience operating a wide variety of power plants—including wood gasification plants, industrial cogeneration plants, and biogas and landfill gas CHP plants. After more than a year of operating a Syncraft plant, I can say that the technology has impressed me both technically and operationally. Particularly noteworthy is the combination of electricity generation, heat utilization, and the production of certifiable biochar (Green Carbon)—to my knowledge, currently unique on the market.”

Reference: Ralph Grauel

Ralph Grauel

Operator, Reversepowerplant
  • CustomerRalph Grauel
  • System Type CW1800-500
  • Electrical power500 kW
  • CO₂ avoided1)3,500 t/a
  • CO₂ extracted 2)1,500 t/a
  • Heat utilizationOwn use (contract drying)
  • Fuel requirement362 kg/h
  • Area215 m²
  • Commissioning2024
  • 1) compared to natural gas
  • 2) permanently extracted via green carbon
20240508_080526 20240508_080543

More customer stories

Reference brochure

COMING SOON
FlipbookSample

Latest references

View all references
Attachments
CW1800 -500

REINTHALMÜHLE / AT

Attachments
CW1800 -500

WALLERN / AT

Attachments
CW1800 -500

WAIERN / AT